Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 105(4): 875-883, 2019 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-31330175

RESUMEN

PURPOSE: To investigate differences between prescribed and postimplant calculated dose in 192Ir high-dose-rate endorectal brachytherapy (HDR-EBT) by evaluating dose to clinical target volume (CTV) and organs at risk (OARs) calculated with a Monte Carlo-based dose calculation software, RapidBrachyMC. In addition, dose coverage, conformity, and homogeneity were compared among the radionuclides 192Ir, 75Se, and 169Yb for use in HDR-EBT. METHODS AND MATERIALS: Postimplant dosimetry was evaluated using 23 computed tomography (CT) images from patients treated with HDR-EBT using the 192Ir microSelectron v2 (Elekta AB, Stockholm, Sweden) source and the Intracavitary Mold Applicator Set (Elekta AB, Stockholm, Sweden), which is a flexible applicator capable of fitting a tungsten rod for OAR shielding. Four tissue segmentation schemes were evaluated: (1) TG-43 formalism, (2) materials and nominal densities assigned to contours of foreign objects, (3) materials and nominal densities assigned to contoured organs in addition to foreign objects, and (4) materials specified as in (3) but with voxel mass densities derived from CT Hounsfield units. Clinical plans optimized for 192Ir were used, with the results for 75Se and 169Yb normalized to the D90 of the 192Ir clinical plan. RESULTS: In comparison to segmentation scheme 4, TG-43-based dosimetry overestimates CTV D90 by 6% (P = .00003), rectum D50 by 24% (P = .00003), and pelvic bone D50 by 5% (P = .00003) for 192Ir. For 169Yb, CTV D90 is overestimated by 17% (P = .00003) and rectum D50 by 39% (P = .00003), and pelvic bone D50 is significantly underestimated by 27% (P = .007). Postimplant dosimetry calculations also showed that a 169Yb source would give 20% (P = .00003) lower rectum V60 and 17% (P = .00008) lower rectum D50. CONCLUSIONS: Ignoring high-Z materials in dose calculation contributes to inaccuracies that may lead to suboptimal dose optimization and disagreement between prescribed and calculated dose. This is especially important for low-energy radionuclides. Our results also show that with future magnetic resonance imaging-based treatment planning, loss of CT density data will only affect calculated dose in nonbone OARs by 2% or less and bone OARs by 13% or less across all sources if material composition and nominal mass densities are correctly assigned.


Asunto(s)
Braquiterapia/métodos , Radioisótopos de Iridio/administración & dosificación , Órganos en Riesgo/efectos de la radiación , Radioisótopos/administración & dosificación , Neoplasias del Recto/radioterapia , Radioisótopos de Selenio/administración & dosificación , Iterbio/administración & dosificación , Braquiterapia/instrumentación , Fémur/efectos de la radiación , Humanos , Método de Montecarlo , Órganos en Riesgo/diagnóstico por imagen , Huesos Pélvicos/efectos de la radiación , Dosificación Radioterapéutica , Recto/efectos de la radiación , Tomografía Computarizada por Rayos X , Vejiga Urinaria/efectos de la radiación
2.
Int J Radiat Oncol Biol Phys ; 97(5): 910-918, 2017 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28333012

RESUMEN

PURPOSE AND OBJECTIVES: Neurologic deficits after brain radiation therapy (RT) typically involve decline in higher-order cognitive functions such as attention and memory rather than sensory defects or paralysis. We sought to determine whether areas of the cortex critical to cognition are selectively vulnerable to radiation dose-dependent atrophy. METHODS AND MATERIALS: We measured change in cortical thickness in 54 primary brain tumor patients who underwent fractionated, partial brain RT. The study patients underwent high-resolution, volumetric magnetic resonance imaging (T1-weighted; T2 fluid-attenuated inversion recovery, FLAIR) before RT and 1 year afterward. Semiautomated software was used to segment anatomic regions of the cerebral cortex for each patient. Cortical thickness was measured for each region before RT and 1 year afterward. Two higher-order cortical regions of interest (ROIs) were tested for association between radiation dose and cortical thinning: entorhinal (memory) and inferior parietal (attention/memory). For comparison, 2 primary cortex ROIs were also tested: pericalcarine (vision) and paracentral lobule (somatosensory/motor). Linear mixed-effects analyses were used to test all other cortical regions for significant radiation dose-dependent thickness change. Statistical significance was set at α = 0.05 using 2-tailed tests. RESULTS: Cortical atrophy was significantly associated with radiation dose in the entorhinal (P=.01) and inferior parietal ROIs (P=.02). By contrast, no significant radiation dose-dependent effect was found in the primary cortex ROIs (pericalcarine and paracentral lobule). In the whole-cortex analysis, 9 regions showed significant radiation dose-dependent atrophy, including areas responsible for memory, attention, and executive function (P≤.002). CONCLUSIONS: Areas of cerebral cortex important for higher-order cognition may be most vulnerable to radiation-related atrophy. This is consistent with clinical observations that brain radiation patients experience deficits in domains of memory, executive function, and attention. Correlations of regional cortical atrophy with domain-specific cognitive functioning in prospective trials are warranted.


Asunto(s)
Corteza Cerebral/patología , Corteza Cerebral/efectos de la radiación , Irradiación Craneana/efectos adversos , Imagen por Resonancia Magnética/métodos , Traumatismos por Radiación/etiología , Traumatismos por Radiación/patología , Adulto , Anciano , Atrofia/etiología , Atrofia/patología , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/radioterapia , Relación Dosis-Respuesta en la Radiación , Humanos , Persona de Mediana Edad , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
3.
Int J Radiat Oncol Biol Phys ; 97(2): 263-269, 2017 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28068234

RESUMEN

PURPOSE: After radiation therapy (RT) to the brain, patients often experience memory impairment, which may be partially mediated by damage to the hippocampus. Hippocampal sparing in RT planning is the subject of recent and ongoing clinical trials. Calculating appropriate hippocampal dose constraints would be improved by efficient in vivo measurements of hippocampal damage. In this study we sought to determine whether brain RT was associated with dose-dependent hippocampal atrophy. METHODS AND MATERIALS: Hippocampal volume was measured with magnetic resonance imaging (MRI) in 52 patients who underwent fractionated, partial brain RT for primary brain tumors. Study patients had high-resolution, 3-dimensional volumetric MRI before and 1 year after RT. Images were processed using software with clearance from the US Food and Drug Administration and Conformité Européene marking for automated measurement of hippocampal volume. Automated results were inspected visually for accuracy. Tumor and surgical changes were censored. Mean hippocampal dose was tested for correlation with hippocampal atrophy 1 year after RT. Average hippocampal volume change was also calculated for hippocampi receiving high (>40 Gy) or low (<10 Gy) mean RT dose. A multivariate analysis was conducted with linear mixed-effects modeling to evaluate other potential predictors of hippocampal volume change, including patient (random effect), age, hemisphere, sex, seizure history, and baseline volume. Statistical significance was evaluated at α = 0.05. RESULTS: Mean hippocampal dose was significantly correlated with hippocampal volume loss (r=-0.24, P=.03). Mean hippocampal volume was significantly reduced 1 year after high-dose RT (mean -6%, P=.009) but not after low-dose RT. In multivariate analysis, both RT dose and patient age were significant predictors of hippocampal atrophy (P<.01). CONCLUSIONS: The hippocampus demonstrates radiation dose-dependent atrophy after treatment for brain tumors. Quantitative MRI is a noninvasive imaging technique capable of measuring radiation effects on intracranial structures. This technique could be investigated as a potential biomarker for development of reliable dose constraints for improved cognitive outcomes.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Hipocampo/efectos de la radiación , Imagen por Resonancia Magnética/métodos , Adulto , Factores de Edad , Anciano , Atrofia/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Femenino , Hipocampo/diagnóstico por imagen , Hipocampo/patología , Humanos , Masculino , Trastornos de la Memoria/etiología , Persona de Mediana Edad , Análisis Multivariante , Tamaño de los Órganos/efectos de la radiación , Estudios Retrospectivos , Factores de Tiempo
4.
Pediatr Dermatol ; 31(6): 741-3, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25424214

RESUMEN

A symptomatic retained foreign body can be frustrating to physicians and patients alike. Herein we present a case of a retained metal ball bearing from an air gun injury. This brief communication highlights an innovative "bedside" technique that helped to confirm the diagnosis and allow for immediate and definitive management.


Asunto(s)
Cuerpos Extraños/diagnóstico , Cuerpos Extraños/cirugía , Heridas por Arma de Fuego/diagnóstico , Heridas por Arma de Fuego/cirugía , Adolescente , Diagnóstico Diferencial , Cejas , Humanos , Fenómenos Magnéticos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...